BNRZV - HEXAFLUOROETHANE, PERFLUOROETHANE, HALOCARB
- MSDS: BNRZV
- Manufacturer: AIR PRODUCTS AND CHEMICALS INC
- Product Name: HEXAFLUOROETHANE, PERFLUOROETHANE, HALOCARB
- National Stock Number: 6830-00N030711
Product Identification
Product ID:HEXAFLUOROETHANE, PERFLUOROETHANE, HALOCARB
MSDS Date:02/01/1987
FSC:6830
NIIN:00N030711
MSDS Number: BNRZV
Responsible Party
ALLENTOWN, PA 18195-1501
US
Emergency Phone: 800-523-9374 OR 800-322-9092
Info Phone: 215-481-8257
Cage: 00742
Contractor
Telephone: 800-345-3148/ 800-752-1597
Cage: 00742
Ingredients
PERIODS OF TIME. USE ONLY IN WELL-VENTD AREAS.
RTECS: 9999999ZZ
SECURED W/VALVE OUTLET PIPED TO USE POINT. DO NOT
RTECS: 9999999ZZ
CYL MOVEMENT. USE A PRESS REDUCING REGULATOR WHEN
RTECS: 9999999ZZ
SYSTEMS. DO NOT HEAT CYL BY ANY MEANS TO INCR
RTECS: 9999999ZZ
IN THE DISCHARGE LINE TO PVNT HAZ BACKFLOW INTO CYL.
RTECS: 9999999ZZ
GAS CATALOG SFTY & TECHNICAL INFORMATION SECTION OR
RTECS: 9999999ZZ
IS NONCORROSIVE & MAY BE USED W/ANY COMMON
RTECS: 9999999ZZ
CATALYSTS FOR THE DECOMP OF HEXAFLUOROETHANE AT HIGH
RTECS: 9999999ZZ
SHOULD NOT BE USED IF WATER IS PRESENT. COMPRESSED
RTECS: 9999999ZZ
PRDCERS OF COMPRESSED GASES. SHIPMENT OF COMPRESSED
RTECS: 9999999ZZ
(WRITTEN) CONSENT IS A VIOLATION OF FEDERAL LAW
RTECS: 9999999ZZ
ETHANE, HEXAFLUORO-; (HEXAFLUOROETHANE)
CAS: 76-16-4
RTECS: KI4110000
IMMED FLUSH W/POTABLE
RTECS: 9999999ZZ
CALL MD IMMEDIATELY .
RTECS: 9999999ZZ
OUTLET SEALS SECURED & VALVE PROT IN PLACE.
RTECS: 9999999ZZ
NUMBER LISTED HEREIN.
RTECS: 9999999ZZ
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:HEXAFLUOROETHANE IS INACTIVE
BIOLOGICALLY & ESSENTIALLY NONTOXIC; THEREFORE, THE MAJOR HAZARD IS
THE EXCLUSION OF AN ADEQUATE SUPPLY OF OXYGEN TO THE LUNGS.
FROSTBITE EFFECTS ARE A CHANGE IN COLOR OF THE SKIN TO GRAY OR
WHITE, POSSIBLY FOLLOWED BY BLISTERING.
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:INHAL: HIGH CONCENTRATION OF HEXAFLUOROETHANE
SO AS TO EXCLUDE AN ADEQUATE SUPPLY OF OXYGEN TO THE LUNGS CAUSE
DIZZINESS, DEEPER BREATHING DUE TO AIR HUNGER, POSSIBLE NAUSEA &
EVENTUAL UNCONSCIOUSNESS . CONTACT W/THE RAPIDLY EVAPORATING LIQUID
CAN CAUSE CRYOGENIC "BURNS" OR FROSTBITE.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
First Aid
First Aid:PROMPT MED ATTN IS REQD IN ALL CASES OF OVEREXP TO
HEXAFLUOROETHANE. RESCUE PERS SHOULD BE EQUIPPED W/APPROP PROT
EQUIP (NIOSH/MSHA APPRVD SCBA, ETC) TO PVNT UNNEC EXPOS.
INHAL:CONSCIOUS PERS SHOULD B E ASSISTED TO UNCONTAMD AREA & INHALE
FRESH AIR. QUICK REMOVAL FROM CONTAMD AREA IS MOST IMPORTANT. UNCON
PERS SHOULD BE MOVED TO UNCONTAMD AREA, GIVEN MOUTH-TO-MOUTH
RESUSCITATION & SUPP (SUPP DATA)
Fire Fighting
Extinguishing Media:NONFLAMMABLE GAS. USE MEDIA SUITABLE FOR
SURROUNDING FIRE CONDITIONS .
Fire Fighting Procedures:WEAR NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP
. IF POSS W/OUT RISK, MOVE CYL AWAY FROM FIRE AREA. FROM A SAFE
DISTANCE, COOL CYL W/WATER SPRAY (SUPP DATA)
Unusual Fire/Explosion Hazard:CYLINDERS EXPOSED TO FIRE OR HEAT MAY
VENT RAPIDLY OR EXPLODE. IF HEXAFLUOROETHANE IS INVOLVED IN A FIRE,
IT MAY DECOMPOSE YIELDING TOXIC PRODUCTS.
Accidental Release
Spill Release Procedures:EVACUATE ALL PERS FROM AFFECTED AREA. USE
APPROP PROT EQUIPMENT. IF LEAK IS IN USER'S EQUIPMENT, BE CERTAIN
TO PURGE PIPING W/AN INERT GAS PRIOR TO ATTEMPTING REPAIRS. IF LEAK
IS IN CYL OR CYL VALVE, CALL THE "800" EMER PHONE NUMBER LISTED.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:PROT CYL FROM PHYSICAL DAM. STORE IN
COOL, DRY, WELL-VENTD AREA AWAY FROM HEAVILY TRAVELED AREAS & EMER
EXITS. FULL & EMPTY CYL SHOULD BE SEGREGATED.
Other Precautions:DO NOT ALLOW TEMP WHERE CYL ARE STORED TO EXCEED
125F. CYL SHOULD BE STORED UPRIGHT & FIRMLY SECURED TO PVNT
FALLING/BEING KNOCKED OVER. USE A "FIRST IN-FIRST OUT" INVENTORY
SYS TO PVNT FULL CYL BEING STORED FOR EXCESSIVE (ING 6)
Exposure Controls
Respiratory Protection:NIOSH/MSHA APPROVED POSITIVE PRESSURE AIR LINE
W/ MASK OR SCBA SHOULD BE AVAILABLE FOR EMERGENCY USE.
Ventilation:USED TO PVNT ACCUM OF HIGH CONC THAT WOULD REDUCE O2 LEVEL
IN AIR BELOW 18% BY VOL. INSURE ADEQ FLOOR LEVEL VENT.
Protective Gloves:ANY BUT NATURAL RUBBER.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:SAFETY SHOES.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
FIRE FIGHT PROC:UNTIL WELL AFTER FIRE IS OUT. FIRST AID PROC:O2.
FURTHER TREATMENT SHOULD BE SYMPTOMATIC & SUPPORTIVE.
SKIN/FROSTBITE:REMOVE CONTAMD CLTHG & FLUSH AFFECTED AREAS W/
LUKEWARM WATER. DO NOT USE HOT WATER. A MD SHOULD SEE PATIENT
PROMPTLY IF THE CRYOGENIC "BURN" HAS RSLTD IN BLISTERING OF SKIN
SURF (ING 2
Chemical Properties
HCC:G3
Boiling Pt:B.P. Text:-109F,-78C
Melt/Freeze Pt:M.P/F.P Text:-149F,-101C
Vapor Pres:445 PSIA
Spec Gravity:4.82 (AIR=1)
Solubility in Water:VERY SLIGHTLY SOL
Appearance and Odor:COLORLESS & ODORLESS GAS.
Stability
Stability Indicator/Materials to Avoid:YES
NONE.
Stability Condition to Avoid:NONE.
Hazardous Decomposition Products:HYDROGEN FLUORIDE & OTHER TOXIC
FLUORIDES AT HIGH TEMPERATURES.
Disposal
Waste Disposal Methods:ALL FED, STATE & LOC REGS REGARDING HLTH &
POLLUTION SHOULD BE FOLLOWED IN WASTE DISP. CONT AIR PRODUCTS FOR
SPECIFIC RECOM. DO NOT DISP OF UNUSED QTYS. RETURN PROPERLY LABELED
SHIPPING CONTR TO AIR P RODUCTS FOR DISP W/VALVES TIGHTLY CLSD,(ING
4)
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.